Skip to content

Troubleshooting

Symptom Cause Fix
plugin:ftsim:ftsim is missing from /mcp, or shown as failed Neither the “OpenModelica folder” setting nor OPENMODELICAHOME is set, so the server has no OpenModelica to start. Set “OpenModelica folder” in /config, or through /plugin > Installed > FT Simulation Assistant > Configure options, then run /reload-plugins. Or set OPENMODELICAHOME to the folder OpenModelica is installed in, then close Claude Code and start it again from a new terminal. See Enter the OpenModelica folder.
plugin:ftsim:ftsim fails in /mcp with OpenModelica found Windows Smart App Control may be blocking ftsim.exe, which isn’t code-signed. Email support@fuentes.technology. FT Simulation Assistant doesn’t run while Smart App Control is on.
The server says “omc wasn’t found in …” The “OpenModelica folder” setting, or OPENMODELICAHOME when that setting is empty, names a folder with no bin\omc.exe, often the bin folder itself. Choose the folder that holds OpenModelica’s bin folder, not bin itself. Set it in “OpenModelica folder” in /config, then run /reload-plugins. Or correct OPENMODELICAHOME, then close Claude Code and start it again from a new terminal.
A changed setting has no effect Claude Code keeps the server it started with until the plugins are reloaded. Run /reload-plugins.
A tool call reports the omc session was restarted omc stopped responding, or its replies got out of step with the commands sent to it, so the server replaced it with a fresh session rather than risk returning the wrong reply. Reload any classes and libraries, and simulate again: classes, libraries and resultFile IDs from before the restart are gone. If the error says no session is available, the next tool call tries again.
A result tool rejects a resultFile ID The ID was never issued, or it was issued before the omc session restarted. The error tells you which. Simulate again to get a fresh ID.

If your problem isn’t listed here, or you have a bug, feature request or question, send it through the feedback form.