The steady-state CSTR model MultiParameterCSTRWithObjectives was searched over feed flow F and feed temperature T0 to maximise Yield of product B while keeping production of B at or above its 0.10 mol/s target (TargetMargin ≥ 0). A 4-round narrowing grid raised Yield from 0.2837 to 0.4035 (+42.2%).
Steady state at the model's nominal design values, before any search — the starting reference for comparison.
F (flow)0.4 m³/s
T0 (feed temp)298.15 K
Yield0.2837
TargetMargin0.0702 mol/s
Conversion0.3278
Selectivity0.8655
Productivity0.1702 mol/s
T (reactor)298.18 K
Search process narrowing grid, 4 rounds
Each round simulates a grid of 16 (4 × 4) points over the current design box, edges included, one simulation per point. The next round's box is half the width, centred on the best feasible point so far.
R1Best feasible Yield = 0.40025 at F = 0.2, T0 = 308.333 K (new best so far). 7 of 16 points infeasible.F 0.05–0.5 m³/s T0 285–320 K
R2Best feasible Yield = 0.39797 at F = 0.2375, T0 = 311.25 K (no improvement on 0.40025; centre kept). 8 of 16 points infeasible.F 0.0875–0.3125 m³/s T0 299.583–317.083 K
R3Best feasible Yield = 0.40281 at F = 0.18125, T0 = 303.958 K (new best so far). 4 of 16 points infeasible.F 0.14375–0.25625 m³/s T0 303.958–312.708 K
R4Best feasible Yield = 0.40348 at F = 0.171875, T0 = 303.229 K (new best so far). 4 of 16 points infeasible.F 0.153125–0.209375 m³/s T0 301.771–306.146 K
Yield vs. each input parameter 66 simulations
One scatter per lever, all sharing the same round coloring — baseline (grey square), each search round, and the confirmed optimum (accent diamond). Hollow markers are infeasible points. A flat-looking panel means that lever has little influence on the objective over the searched range; a sloped or curved one means it's a real driver.
Recommended operating point converged optimum
Maximum feasible yield
Yield = 0.4035 at F = 0.171875 m³/s, T0 = 303.229 K